996 resultados para vital parameters


Relevância:

70.00% 70.00%

Publicador:

Resumo:

This preliminary compilation presents vital parameters for 22 species of freshwater fish from Lake Kariba. The majority of the growth parameters are derived from tables in Balon and Coche's "Lake Kariba: a man-made tropical ecosystem in central Africa". The rest of the parameters are compiled from more recent sources and unpublished data.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tese de mestrado, Cuidados Paliativos, Faculdade de Medicina, Universidade de Lisboa, 2015

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Wireless Body Area Networks (WBANs) consist of a number of miniaturized wearable or implanted sensor nodes that are employed to monitor vital parameters of a patient over long duration of time. These sensors capture physiological data and wirelessly transfer the collected data to a local base station in order to be further processed. Almost all of these body sensors are expected to have low data-rate and to run on a battery. Since recharging or replacing the battery is not a simple task specifically in the case of implanted devices such as pacemakers, extending the lifetime of sensor nodes in WBANs is one of the greatest challenges. To achieve this goal, WBAN systems employ low-power communication transceivers and low duty cycle Medium Access Control (MAC) protocols. Although, currently used MAC protocols are able to reduce the energy consumption of devices for transmission and reception, yet they are still unable to offer an ultimate energy self-sustaining solution for low-power MAC protocols. This paper proposes to utilize energy harvesting technologies in low-power MAC protocols. This novel approach can further reduce energy consumption of devices in WBAN systems.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Health monitoring technologies such as Body Area Network (BAN) systems has gathered a lot of attention during the past few years. Largely encouraged by the rapid increase in the cost of healthcare services and driven by the latest technological advances in Micro-Electro-Mechanical Systems (MEMS) and wireless communications. BAN technology comprises of a network of body worn or implanted sensors that continuously capture and measure the vital parameters such as heart rate, blood pressure, glucose levels and movement. The collected data must be transferred to a local base station in order to be further processed. Thus, wireless connectivity plays a vital role in such systems. However, wireless connectivity comes at a cost of increased power usage, mainly due to the high energy consumption during data transmission. Unfortunately, battery-operated devices are unable to operate for ultra-long duration of time and are expected to be recharged or replaced once they run out of energy. This is not a simple task especially in the case of implanted devices such as pacemakers. Therefore, prolonging the network lifetime in BAN systems is one of the greatest challenges. In order to achieve this goal, BAN systems take advantage of low-power in-body and on-body/off-body wireless communication technologies. This paper compares some of the existing and emerging low-power communication protocols that can potentially be employed to support the rapid development and deployment of BAN systems.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

 This thesis contains fundamental studies of the deformation mechanisms of the third generation steel at different deformation temperatures. To analyse the microstructure of the steel a unique characterisation technique was implemented for the first time. These analyses provided with vital parameters for modelling the stress-strain behaviour of the steel at different deformation temperatures.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective The aim of the present study was to evaluate the effects of nitrous oxide on TOP and pupillary diameter (PD) of dogs anesthetized with varying desflurane concentrations.Animals studied Twenty adult Mongrel dogs were used.Methods They were anesthetized with propofol (10 mg/kg, IV) and maintained with varying concentrations of desflurane (1.6, 1.4, and 1.2 MAC diluted in 100% oxygen (G1) or in 70% nitrous oxide and 30% oxygen (G2) (30 mL/kg/min). TOP was measured by applanation tonometry and horizontal PD was taken with a caliper adjacent to the cornea. Mean arterial pressure (MAP), heart rate (HR), respiratory rate (RR), and end-tidal CO, (etCO(2)) were also measured. All parameters were measured at TO, T30, T45, and T60 time points. One-way repeated measures ANOVA and the t-test were used to assess statistical differences (P < 0.05).Results T30, T45, and T60 TOP measures were Within normal limits for both groups and TOP did not differ between groups at any time. There was a significant decrease in PD in G I between TO and T30, T45 and T60, and also between T30 and T60. PD did not differ between groups. All vital parameters were within normal limits throughout anesthesia.Conclusions Administration of nitrous oxide with desflurane results in maintenance of normal TOP and prevents a decrease in horizontal PD during anesthesia. Therefore, this may be a suitable protocol in dogs undergoing intraocular surgeries that require mydriasis and maintenance of normal TOP.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The elective ovariohysterectomy (OH) is the most frequent procedures performed in dogs. In this study was used three groups of seven animals each (GI, GII, and GIII) that was undergone to three elective OH techniques: (i) mini-celiotomy (Snook-hook technique), (ii) hybrid Natural Orifice Translumenal Endoscopic Surgery (NOTES), and (iii) celiotomy (conventional surgery). The surgical techniques were compared considering the surgery time, trans and postoperative complications, technical difficulties, postoperative pain, surgical bleedind and some vital parameters as: heart rate (FC), respiratory rate (), rectal temperature, invasive blood pressure (PVI) and central venous pressure (PVC). The OH by hybrid vaginal NOTES was the technique with the lowest post-surgical discomfort score and the lowest surgical bleeding, although its surgical time was higher compared to the conventional and the hook (mini-celiotomy) modalities.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of the study was to evaluate the influence of glucocorticoids on vital parameters of full-term and preterm lambs from birth to 48 hours of life. Four experimental groups were formed: NDG (normal delivery group - lambs vaginally delivered, n=15, average of 146-day gestation); NDEXG (normal delivery with dexamethasone group - lambs vaginally delivered whose mothers received 16mg of dexamethasone at 141 days of gestation, n=8, average of 143-day gestation); PRE (premature lambs born by cesarean section at 138 days of gestation, n=10) and PREDEX (premature lambs born by cesarean section at 138 days gestation, whose mothers received 16mg of dexamethasone two days before, n=9). Heart and respiratory rates had variations during the observation period, with the highest mean values in the groups of normal deliveries (NDG and NDEXG). Rectal temperature decreased in all groups in the first 60 minutes of life, with the lowest mean values in premature lambs (PRE and PREDEX) and the Apgar score was higher in animals delivered at normal gestational time. Preterm lambs had lower vitality and chance of survival, however, lower mortality rate was observed in offspring of ewes that received dexamethasone two days before surgery.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

REASONS FOR PERFORMING STUDY: Efficacy of medications for recurrent airway obstruction is typically tested using clinical, cytological and lung function examinations of severely affected animals. These trials are technically challenging and may not adequately reflect the spectrum of disease and owner complaints encountered in clinical practice. OBJECTIVE: To determine if owners of horses with chronic airway disease are better able to detect drug efficacy than a veterinarian who clinically examines horses infrequently. METHOD: In a double-blinded randomised controlled trial, owners and a veterinarian compared the efficacy of dexamethasone (0.1 mg/kg bwt per os, q. 24 h, for 3 weeks; n = 9) to placebo (n = 8) in horses with chronic airway disease. Before and after treatment, owners scored performance, breathing effort, coughing and nasal discharge using a visual analogue scale (VAS). The clinician recorded vital parameters, respiratory distress, auscultation findings, cough and nasal discharge, airway mucus score, bronchoalveolar lavage fluid (BALF) cytology and arterial blood gases. RESULTS: The VAS score improved significantly in dexamethasone- but not placebo-treated horses. In contrast, the clinician failed to differentiate between dexamethasone- and placebo-treated animals based on clinical observations, BALF cytology or endoscopic mucus score. Respiratory rate (RR) and arterial oxygen pressure (PaO(2)) improved with dexamethasone but not placebo. CONCLUSIONS AND CLINICAL RELEVANCE: In the design of clinical trials of airway disease treatments, more emphasis should be placed on owner-assessed VAS than on clinical, cytological and endoscopic observations made during brief examinations by a veterinarian. Quantifiable indicators reflecting lung function such as RR and PaO(2) provide a good assessment of drug efficacy.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In her book 'Living on Light', Jasmuheen tries to animate people worldwide to follow her drastic nutrition rules in order to boost their quality of life. Several deaths have been reported as a fatal consequence. A doctor of chemistry who believably claimed to have been 'living on light' for 2 years, except for the daily intake of up to 1.5 l of fluid containing no or almost no calories was interested in a scientific study on this phenomenon. PARTICIPANT AND METHODS: The 54-year-old man was subjected to a rigorous 10-day isolation study with complete absence of nutrition. During the study he obtained an unlimited amount of tea and mineral water but had no caloric intake. Parameters to monitor his metabolic and psychological state and vital parameters were measured regularly and the safety of the individual was ensured throughout the study. The subject agreed on these terms and the study was approved by the local ethics committee.